Skip to content
Skip to content
PakMCQ
Practice
Mock Tests
Browse
Leaderboard
Search questions
Sign in
Home
›
Prep
›
Browse
›
Chemical Engineering
›
Process Control and Instrumentation
Process Control and Instrumentation
314 questions
Practise this subject
Questions
Stability of a control system containing a transportation lag can be best analysed by_______________?
Show answer
Answer:
Frequency response methods
Accurate temperature measurement performance of a radiation pyrometer cannot be affected, if the ?
Show answer
Answer:
Object and surrounding are at almost the same temperature
The open loop transfer function of a process is K [{(s + 1) (s + 4)}/{(s + 2) (s + 3)}]. In the root locus diagram, the poles will be at ___________________?
Show answer
Answer:
-2, -3
Feed forward controller accounts for the ______________ changes?
Show answer
Answer:
Load
Thermal wells are used in the temperature measurement to____________________?
Show answer
Answer:
Guard against corrosive and oxidising action on thermocouple materials
Liquid flow rate in a small channel is best measured by a/an____________________?
Show answer
Answer:
Pitot tube
A first order system with a time constant of 1 min is subjected to frequency response analysis. At an input frequency of 1 radian/min, the phase shift is______________?
Show answer
Answer:
-45°
Pick out the most suitable instrument for measuring temperature in the range of-40 to 425°C ?
Show answer
Answer:
Bimetallic thermometer
What is the normal percentage of rhodium in platinum + rhodium element used in the thermocouple ?
Show answer
Answer:
13
Cascade control means _______________?
Show answer
Answer:
More than one feed-back loop
In Bode plot, φ vs. ω is plotted on a/an ______________ graph paper?
Show answer
Answer:
log-log
Which of the following thermocouples has the widest temperature measurement range ?
Show answer
Answer:
Platinum-platinum/rhodium
The thermal emf-temperature relationship of most thermocouples is_________________?
Show answer
Answer:
Parabolic
_____________ is an example of distributed parameter system ?
Show answer
Answer:
Tubular reactor
Which of the following can measure temperatures in the range of – 20 to 300°C ?
Show answer
Answer:
None of these
The level of a liquid under pressure can be determined using___________________?
Show answer
Answer:
Differential pressure manometer
In Bode plot, A.R. vs. w is plotted on a/an _____________ graph paper?
Show answer
Answer:
Log-lag
Temperature control of an exothermic chemical reaction taking place in a CSTR is done with the help of cooling water flowing in a jacket around the reactor. The types of valve and controller action to be recommended are________________?
Show answer
Answer:
Air to open valve with the controller indirect acting
Thermal well made of _____________ gives the fastest speed of response, while measuring temperature by thermocouples?
Show answer
Answer:
Vycor (a glass)
With increase in temperature, the electrical conductivity of the platinum used in the resistance thermometer ?
Show answer
Answer:
Decreases
‹ Previous
1
2
3
4
5
6
…
16
Next ›
Home
Practice
Tests
Browse
Sign in
You are offline. Your answers are kept on this device and will sync when you are back online.