Skip to content
Skip to content
PakMCQ
Practice
Mock Tests
Browse
Leaderboard
Search questions
Sign in
Home
›
Prep
›
Browse
›
Chemical Engineering
›
Process Control and Instrumentation
Process Control and Instrumentation
314 questions
Practise this subject
Questions
In a shell and tube heat exchanger, the outlet temperature of heating/cooling fluid is the _____________ variable?
Show answer
Answer:
Controlled
Continuous measurement of specific gravity of a liquid is done by __________________?
Show answer
Answer:
Both A. and C.
Which of the following is not classified as a thermo electric pyrometer ?
Show answer
Answer:
Optical pyrometer (disappearing filament type)
If response of a control system is to be free of offset and oscillation, the most suitable controller is_________________?
Show answer
Answer:
Proportional integral-derivative (PID) controller
For two non-interacting first order systems connected in series, the overall transfer function is the ______________ of the individual transfer functions?
Show answer
Answer:
Product
Which of the following thermocouples is capable of measuring a temperature of -50°C ?
Show answer
Answer:
Platinum-platinum + rhodium
Reference points i.e., ice point and steam point in Reaumer temperature scale are respectively_________________?
Show answer
Answer:
0° & 80°
Non-metallic diaphragm used as pressure sensor in instruments is generally made of__________________?
Show answer
Answer:
Synthetic rubber
In second order underdamped system ?
Show answer
Answer:
Decay ratio = (overshoot)2
Bimetal strips are not used in________________?
Show answer
Answer:
Thermocouples
A manometer measures the _____________ pressure?
Show answer
Answer:
Gauge
Compositional analysis of flue gas coming out of a furnace in respect of O2 and CO2% can be continuously done by a/an___________________?
Show answer
Answer:
Thermal conductivity cell
Mercury thermometer is commonly used for low temperature measurement. The freezing point and boiling point of mercury are respectively _____________ °C?
Show answer
Answer:
– 39 and 350
A stable system is the one___________________?
Show answer
Answer:
For which the output response is bounded for all bounded input
Routh test_________________?
Show answer
Answer:
Cannot be used to test the stability of a control system containing transportation lag
Thermodynamic Celsius scale of temperature measurement is________________?
Show answer
Answer:
Both B. and C.
Bourdon gauges are used for measuring pressure (kg/cm2) ?
Show answer
Answer:
> 2 (gauge)
Radiation pyrometers as compared to thermocouples____________________?
Show answer
Answer:
Can measure higher temperature
Number of poles in a system with transfer function 1/(s2 + 2s2 + 1) is ________________?
Show answer
Answer:
3
Thermocouple in a thermal well behaves as a true ________________?
Show answer
Answer:
Multiple first order system
‹ Previous
1
2
3
4
5
…
16
Next ›
Home
Practice
Tests
Browse
Sign in
You are offline. Your answers are kept on this device and will sync when you are back online.
Install PakMCQ App
Practice faster with offline access!
Install
×
×
Install PakMCQ
Add to your iPhone / iPad Home Screen
1
Tap the
Share
button
at the bottom of Safari
2
Scroll down and select
Add to Home Screen
3
Tap
Add
in the top-right corner